MANAGEMENT OF BLOW-OUT FRACTURE INJURY SECONDARY A FIREARM BY USING A FOLEY CATHETER: A CASE REPORT

Authors

  • Carlos Ernesto Rueda Torres U. Santo Tomás
  • Julio Martín Ruiz Roa U. Santo Tomás

DOI:

https://doi.org/10.15332/us.v9i1.1167

Keywords:

Blow-out fractures, Diplopy, Foley catheter, Orbital floor

Abstract

Orbital fractures are associated to high-energy blunt hits on the eyeball; they involve the orbital floor and lateral wall at least in all the cases. Treatment will be taken accord to the eyeball compromise. This paper shows a patient case, 22 years old, who worked at the police department. He was fire gun injured penetrating and high-speed type. There were compromised the upper ascendant maxillary apophysis, orbital floor and lateral wall of the orbit, zigomatic-malar complex bone, maxillary sinus. The surgery procedure included the wound cleaning, the stabilization and the reduction of the fracture, orbital and facial reconstruction. The objective of this case report was to increase the knowledge of Foley catheter likeness antral stopper during orbital-malar fractures during blow-out fractures reconstruction.

Downloads

Download data is not yet available.

Author Biographies

Carlos Ernesto Rueda Torres, U. Santo Tomás

Odontólogo U. Santo Tomás, Cirujano Maxilofacial U. Javeriana, Docente U. Santo Tomás

Julio Martín Ruiz Roa, U. Santo Tomás

Estudiante X semestre F. de Odontología U. Santo Tomás

References

Castillo D, Mogensen M, Blanco S, Kauan M, Gudiño R. Prevalencia de fracturas en los maxilares de los pacientes que acudieron al servicio de cirugía maxilofacial del Hospital Clínico Universitario (HCU). Acta Odontol Venez 2006; 44: 357 - 363.

Olate S, Alister HJP, Chaves Netto DD, Jaimez M, Mazzonetto R. Reconstrucción de piso de órbita con malla de titanio en trauma de tercio medio facial. Int J Odontostomat 2008; 2: 163 - 170.

Yupanqui A, Martínez AY. Injerto autólogo de calota craneana para reconstrucción de piso de órbita en trauma facial. Reporte de caso. Rev Estomatol Herediana 2005; 15: 168 - 170.

Avello F, Avello A. Nueva clasificación de las fracturas de trazo unilateral. An Fac Med Lima 2007; 68: 75 - 79.

Vila N, Sanz J, Robredo J, Gil M, Atalaya F. Cirugía maxilofacial. Med Clin (Barc) 2005; 124: 26 - 28.

Casarramona F, Belda V, Cruz J, Pou R, Cruz J, Daza M, Cuadrada C. Enfisema palpebral por fractura de la lámina papirácea del etmoides. Emergencias 2003; 15: 247 - 249

Caminal J, Prat J, Arruga J. Fracturas puras del suelo orbitario: actitud terapéutica. Publicaciones Nexus [en línea] 1994; [fecha de acceso: noviembre de 2009]. URL disponible en: http://www.nexusediciones.com/np_ao_1994_4_3_002.htm

Salej S, Pedraza B, Pinzón M. Manejo quirúrgico de las fracturas orbitarias. Hospital de San José, 1997-2002. Repertorio de Medicina y Cirugía 2003; 12: 61 - 65

Ugrin C, Weil D. Transtornos oculomotores en las fracturas de órbita. [En línea] URL disponible en: http://www.plasticaocular.com/trabajos/orbita/trastornos_oculomotores_en_las_fracturas_orbitales

Burm J, Cheng CH. Pure orbital blowout fractures: new concepts and importance of medial orbital blow out fracture. Plastic Reconstr Surg 1999; 103: 1839 - 1849.

Moore K, Dalley A. Anatomía con Orientación Clínica. Editorial Panamericana, 5ta. Edición; México. p. 960 - 973.

Tortora G, Derrickson B. Anatomía y Fisiología. Editorial Oxford, 9na. Edición, pág. 321 - 322.

Latarjet M, Ruiz A. Anatomía Humana. Editorial panamericana, 4ta. Edición, pag. 414-417.

Zambrano J, Leyva C. Lesiones oculares y perioculares asociadas a los traumatismos de órbita. Cir Plast Iberolatinoame 2007; 33: 233 - 242.

Rhee J, Kilde J, Yoganadan N, Pintar F. Orbital Blowout fractures experimental evidence for the pure hydraulic theory. Arch Facial Plast Surg 2002; 4: 98 - 101.

Muñoz J, Gutiérrez J, Zubizarreta F. Organización en el tratamiento del traumatismo panfacial y de las fracturas complejas del tercio medio. Cir Plast Iberolatinoam 2009; 35: 43 - 54.

Díaz JM, Góngora R. Estudio comparativo sobre la estabilización de las fracturas cigomáticas. Rev Cubana Estomatol 1996; 33 [en línea]. [fecha de acceso: octubre de 2009]. URL disponible en: http://bvs.sld.cu/revistas/est/vol33_3_96/est06396.htm

Simsek T, Keskin M, Eroglu L. The extended uses of Foley catheter in plastic surgery. Indian J Plast Surg 2006; 39: 111 - 116.

Sveinsson E. Pure “blow-out” fractures of the orbital floor. J Laryngol Otol 1973; 87: 465 - 473.

Hong R, Yeon J, Shin S, Choi Y. Endoscopic versus external repair of orbital blowout fractures. Otolaryngology Head Neck Surg 2007; 136: 38 - 44.

Booth W, Schendel P, Hausamen A. Maxillofacial surgery 1999; volume 1, pag 256 - 260, Churchill livingstone.

Rothman M, Simon E, Zoarski G, Zagardo M. Superior blowout fracture of the orbit: the blowup fracture. Am J Neuroradiol 1998; 19: 1448 - 1449.

Livingston R, White N, Catone G, Thomas RF. Treatment of orbital fractures by an infraorbital-transantral approach. J Oral Surg 1975; 33: 586 - 590.

Kazanjian V, Converse J, Fracture of the zigoma, suspension method 1933; Surgical Treatment of Facial Injuries; Baltimore, 1974. pp 345 - 357

Rowe N, Williams J. Fractures of the zygomatic complex and orbit, Maxillofacial Injuries. Vol 1. London, Churchill- Livingstone, 1985, pp 435 - 537.

Wangerin K, Busch H, Conrad H. Complication incidence of zygomatic bone fractures using different operation methods, oral and maxillofacial surgery: proceedings from the 8th international conference on oral and maxillofacial surgery, Chicago, Quintessence 1985, pp 1133 - 1159

Fain J, Peri G, Thenoven V. The use of single frontozigomatic osteosynthesis plate and a sinus balloon in the repair of the lateral middle third of the face. J Maxillofac Surg 1981; 9: 188 - 193.

McCoy F, Chandler R, Magnan C. Fracture of the zigoma, Plast Reconstr Surg; 29: 381 - 398.

Finlay P, Ward R, Moos K. Morbidity association with the use of antral packs and external pins in the treatment of the unstable fracture of the zigomatic complex. Br J Oral Maxillofac Surg 1998; 22: 18 - 26.

Published

2010-01-01

How to Cite

Rueda Torres, C. E., & Ruiz Roa, J. M. (2010). MANAGEMENT OF BLOW-OUT FRACTURE INJURY SECONDARY A FIREARM BY USING A FOLEY CATHETER: A CASE REPORT. Ustasalud, 9(1), 50–56. https://doi.org/10.15332/us.v9i1.1167

Issue

Section

Case reports