APEX LOCATOR IN ROOT CANAL TREATMENT
DOI:
https://doi.org/10.15332/us.v2i1.1851Keywords:
Apex locator, Cemento-Dentino-Canal junction (CDC), Apical constriction, Electrical resistanceAbstract
During the accomplishment of a root canal treatment is the vital importance to determine the work length, since it limits the extention of the cleaning, shaping and later filling of the root canal system. There are different methods for the location from the apical constriction or Cemento-Dentino-Canal junction (CDC): the tactile method, the radiographic and electronic methods, like apical locators, that work using three basic principles. Those principles are the electrical resistance, the frequency or impedance and the average of several frequencies, being the last one, the one that provides the precise results and allow to locate the apical constriction in the presence of moisture, blood, fluids, electrolytic substances like the sodium hypochlorite and vital or non vital pulp. Although this method diminishes the working time, does not replace the use of the x-rays. It complement and increase to the number of successes in roots canals therapy
Downloads
References
West J, Roane J. Sistema de limpieza y conformación de los canales radiculares. Cohen S., Burns R. Vías de la Pulpa. Séptima Edición. Madrid. Editorial Harcourt - Mosby. 1999. 209 - 211
Walton - Torabinejad. Endodoncia principios y Práctica. McGraw-Hill. Segunda Edición. México 1996. 211-21, 558
Rivas Muñoz R. Uso y eficacia del localizador del foramen fisiológico, Apex Finder 7001. URL: http://www.iztacala.unam.mx/~rrivas/apexfinder.html
Pratten DH, McDonald NJ. Comparison of radiographic and electronic working lengths. J Endod 1996; 22: 173 - 176.
McDonald NJ, Hovland EJ. An evaluation of the apex locator endocater. J Endod 1990; 16: 5 - 8.
Ounsi HF, Haddad G. In vitro evaluation of the reliability of de Endex electronic Apex locator. J Endod 1998; 24: 120 - 121.
Kobayashi C. Electronic canal length measurement. Oral Surg Oral Med Oral Pathol 1995; 79: 226 - 231.
Kobayashi C. New electronic canal measuring deveice based on the ratio method. J Endod 1994; 20: 111 - 114.
Oishi A, Yoshioka T, Kobayashi C, Suda H. Electronic detection of root canal constriction J Endod 2002; 28: 361 - 364.
Hembrough J, Weine F, Pisano J., Eskoz N. Accuracy of an electronic apex locator: a clinical evaluation in maxillary molars. J Endod. 1993; 19: 242 - 246
Ibarrola JL, Chapman B, Howard JH, Knowles KI, Ludlow MO. Effect of prefaring on Root ZX apex locators. J Endod 1999; 25: 625 - 626.
Jenkins W, Schindler F. An in vitro evaluation of the accuracy of the root ZX in presence of various irrigants. J Endod 2001; 27: 209 - 211.
Frank AL, Torabinejad M. An In vivo evaluation of endex apex locator. J Endod 1993; 19: 177 - 179.
Bramamnte C. A critical evaluation of some methods of determining tooth length. Oral Surg Oral Med Oral Pathol 1974; 37: 463 - 469.
Shabahang S, Goon WY, Gluxkin AH. An in vivo evaluation of root ZX electronic apex locator. J Endod 1996; 22: 616 - 617.
Keller M, Brown C, Newton C. A clinical evaluation of endocater. An electronic apex locator J Endod 1991; 17: 271 - 274.
Czerw RJ, Fulkerson M, Donnelly JC, Walman JO. In Vitro Evaluation of the Accuracy of Several Electronic Apex Locators. J Endod 1995; 21: 572 - 575
Pommer O, Stamm. O, Attin T. Influence of the canal contents on the electrical assisted determination of Length of Root Canals. J Endod 2002; 28: 83 - 85
Pilot TF, Pitts DL. Determination of impedance changes at varying frequencies in relation to root canal position and irrigant. J Endod1997; 23: 719 - 723
Cemal Tinaz A, Sibel Sevimli L, Güliz G, Emin G. The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device. J Endod 2002; 28: 160 - 162.
Beach CW, Douglas J, Jeffrey W. Use of an electronic apex locator on a cardiac pacemaker patient. J Endod 1996; 22: 182 - 184.
Weiger R, John X, Geigle H y Löst C. An in vitro comparison of two modern apex locators. J Endod 1999; 25: 765 - 68.
Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the root ZX electronic apex locator. J Endod 1998; 24: 438 - 441.
Briceño B, Hähnel P, Willersheusen. Reliability of electronic apex locator to determine the working length under moisture conditions. J Endod 2000; 26: 551.
Campbell D, Friedman S, Nguyen HQ, Kaufman A, Keila S. Apical extent of rotary canal instrumentation with an apex- locating hand piece in vitro. Oral Surg Oral Med Oral, Pathol Oral Radio 1998; 85: 319- 324.
Park JW. Tri Auto ZX in locating apical foramen with rotary. (Abstract) J Endod 2000; 26: 561
Chaparro A, Murillo del Castillo C, Haffner C, Benz C, Hickel R. Sistema Endox: desvitalización y esterilización electrónica. Estudio clínico. URL: http://www.ueda.es/articulos/Art%20avances.htm










