IN VITRO EVALUATION OF THE EFFECTIVENESS OF THE APICAL LOCATOR ROOT ZX IN PRESENCE OF SODIUM HYPOCHLORITE COMBINED WITH RC - PREP OR EDTA COMPARED WITH SCANNING ELECTRON MICROSCOPE
DOI:
https://doi.org/10.15332/us.v2i2.1845Keywords:
Root ZX, Cement-Dentin-Canal junction (CDC), sodium hypochlorite, Rc - Prep, EDTAAbstract
Purpose: To assess the effectiveness of the Root Zx to determine the Cement - Dentin - Canal junction (CDC) in the presence of sodium hypochlorite 5,25% Clorox®; combined with Rc- prep. Premier® and sodium hypochlorite 5.25% Clorox® combined with EDTA 10% Eufar® in uniradicular teeth.
Material and methods: An experimental study in vitro with 12 uniradicular teeth was done. They wered divided in three groups: Grupo 1 (n = 12) sodium hypochlorite 5,25% Clorox ®; Group 2 (n = 6) sodium hypochlorite 5.25%Clorox® combined with Rc- Prep. Premier®; Group 3 (n = 6) sodium hypochlorite 5,25% Clorox ® combined with EDTA 10% Eufar®. Root ZX was used to locate the CDC; the samples were divided longitudinally, covered with gold and observed at the SEM, to corroborate the effectiveness of the instrument in the location of the CDC.
Results: The results demonstrate statistically significant differences between Root ZX and SEM in each group. In group 1, a longer measurement was obtained with the Root ZX compared with the SEM, the difference was 0.788 mm. On the other hand, in the group of the sodium hypochlorite 5,25% with EDTA 10%, a shorter measurement was obtained, (-0.766 mm) a statistically significant difference.
Conclusions: The results suggest that the Root ZX is effective in the location of the apical constriction with a level of tolerance of +/- 1 mm.
Downloads
References
West J, Roane J. Sistema de limpieza y conformación de los canales radiculares. En: Cohen S, Burns R. Vías de la Pulpa. 7ma ed. Madrid: Editorial Harcourt- Mosby; 1999. p. 209 - 211.
Nahmias J, Aurelio J, Gerstein H. An in vitro model for evaluation for electronic root canal length measuring devices. J Endod 1987; 13: 209 - 214.
Walton Torabinejad M. Endodoncia principios y Práctica. 2nda ed. México: Mc Graw-Hill; 1996.
McDonald NJ, Hovland EJ. An evaluation of the apex locator Endocater. J Endod 1990; 16: 5 - 8.
Kuttler Y. Microscopic investigation of root apexes. J Am Dent Assoc.1955; 50: 544 - 552.
Hembrough JH, Weine FS, Pisano JV, Eskoz N. Accuracy of an electronic apex locator: A clinical evaluation in maxillary molars. J Endod 1993; 19: 242 - 246.
Ibarrola JL, Chapman B, Howard JH, Knowles KI. Effect of preparing on root ZX apex locators. J Endod 1999; 25: 625 - 626.
Jenkins JA, Walker WA. An in vitro evaluation of the accuracy of the Root ZX in presence of various irrigants. J Endod 2001; 27: 209 - 211.
Imao S. Nuevo método para medir la longitud de trabajo. J Dent Res 1962; 41: 375 - 387.
Shabahang S, Goon WY, Gluxkin AH. An in vivo evaluation of Root ZX electronic apex locator. J Endod 1996; 22: 616 - 617.
Pratten DH, McDonald NJ. Comparison of radiographic and electronic working lengths. J Endod 1996; 22: 173 -176.
Kobayashi C. New electronic canal measuring device based on the ratio method. J Endod 1994; 20: 111 - 114.
Frank AL, Torabinejad M. An in vivo evaluation of endex apex locator. J Endod 1993; 19: 177 - 179.
Bramamnte C. A critical evaluation of some methods of determining tooth length. Oral Surg Oral Med Oral Pathol 1974; 37: 463 - 469.
Weiger R, John X, Geigle H y Löst C. An in vitro comparison of two modern apex locators. J Endod 1999; 25: 765 - 768.
Donnelly JC. Simplified model to demonstrate the operation of electronic root canal measuring devices. J Endod.1993; 19: 579 - 580.
Kaufman, Katz J. Reliability of root ZX apex locator tested by an in vitro model. J Endod 1993; 19: 20 [Abstract].
Ounsi HF, Naaman A. In vitro evaluation of reliability of the Root ZX electronic apex locator. Int J Endod 1999; 32: 120 - 123.
Pagano M, Gauvreau K. Principles of biostatistics. Belmont: Duxbury Press; 1993.
Bland E, Altman D. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 8: 307 - 310.
Ponce E, Fernández JA. The cemento dentino canal - junction, the apical foramen and the apical constriction: Evaluation by optical microscopy. J Endod 2003; 29: 214 - 219.
Rivas Muñoz R. Uso y eficacia del localizador del foramen fisiológico, apex finder 7001.URL disponible en: http://www.iztacala.unam.mx/~rrivas/apexfinder.html.
Keller ME, Brown CE J, Newton CW. A clinical evaluation of Endocater - An electronic apex locator. J Endod. 1991; 17: 271 - 274.
Fouad AF, Rivera EM, Krell KV. Accuracy of endex with variations in canal irrigants and foramen size. J Endod 1993; 19: 63 - 67.
Mayeda DL, Simon JH, Aimar DF, Finley K. In vivo measurements accuracy in vital and necrotic canals with the endex apex locator. J Endod 1993; 19: 545 - 548.
Kobayashi C. Electronic canal length measurement. Oral Surg Oral Med Oral Pathol 1995; 79: 226 -231.
Ounsi HF, Haddad G. In vitro evaluation of the reliability of the endex electronic apex locator. J Endod 1998; 24:120 - 121.
Pagavino G, Pace R, Baccetti T. A SEM study of in vivo accuracy of the Root ZX electronic apex locator. J Endod 1998; 24: 438 - 441.
Cruz-Filho AM, Sousa-Neto MD, Saquy PC, Pecora JD. Evaluación del efecto del EDTAC, CDTA Y EGTA sobre la microdureza dentinal. J Endod 2001; 27: 183 - 184.
Pilot TF, Pitts DL. Determination of impedance changes at varying frequencies in relation to root canal position and irrigant. J Endod 1997; 23: 719 - 724.
Tinaz AC, Sevimli LS, Gorgul G, Turkoz EG. The effects of sodium hypochlorite concentrations on the accuracy of an apex locating device. J Endod 2002; 28:160 - 162.
Comunicación personal con la Ingeniera Zarith Pachón, Ingeniera Química, Instituto Colombiano de Petróleos (ICP). Piedecuesta, Santander, 11 de mayo de 2003.










