Metallographic study of the cutting speed effect on the Ti-6Al4 V ELI microstructure for the company Quirúrgicos Especializados
DOI:
https://doi.org/10.15332/iteckne.v11i1.527Palabras clave:
Biomaterials, Cutting Process, Metallography, Microstructural effect, Ti6Al4V ELI.1Resumen
Current mechanical forming processes used in the production of surgical Ti6Al-4V ELI devices create an undesired microstructural effect that reduces the mechanical properties of the material, thus affecting its performance while in service. In this work we study the microstructural effect that take place in the cutting pro- cess of Ti-6Al4V ELI with the goal of selecting the best available cutting conditions for Quirúrgicos Especial- izados company needs. The cutting process offers two conditions to control rotation and lineal feed speed in the cutting tool. For this work we cut six samples of Ti- 6Al-4V ELI, each sample had different conditions to be metallographically analyzed via optical microscopy. We observed a modification on the Ti-6Al-4V ELI microstruc- ture and a qualitative effect on the mechanical proper- ties have been estimated, allowing the selection of the more efficient conditions in the cutting process.
Descargas
Citas
V.P. Astakhov and M. O. M. Osman, “Correlations amongst process parameters in metal cutting and their use for establishing optimum cutting speed,” in Journ of Mat. Processing Technology, vol. 62, no. 1, 175-179, 1996.
W. Niuet, M. J. Bermingham, P. S. Baburamani, S. Palanisamy, M. S. Dargusch, S. Turk, B. Grigson, and P. K. Sharp, “The effect of cutting speed and heat treatment on the fatigue life of grade 5 and grade 23 Ti-6Al-4V ELI alloys,” in Materials and Design, vol. 46, pp. 640-644, 2013.
L.T. Tunç, “Effect of cutting conditions and tool geometry on process damping and machining,” in International Journ of Mach. Tools & Manufacture, vol. 57, pp. 10-19, 2012.
P. M. de O. Silva, “Cold deformation effect on the microstructures and mechanical properties of AISI 310 LN and 316 L Stainless Steel,” in Materials and Design, vol. 32, pp. 605-614, 2011.
M. Geethaet, A. K. Singh, K. Muraleedharan, A. K. Gogia, and R. Asokamani, “Effect of thermomechanical processing on microstructure of a Ti-13Nb-13Zr alloy,” in Journ of Alloys and Compounds, vol. 329, no. 1, pp. 264-271, 2001.
.J.F. Shackelford, “Difusión,” en Introducción a la Ciencia de los Materiales para Ingenieros, cap. 5, 8va Ed. Madrid, 2005.
A.S.M. Metal Handbook. “Atlas of microstructures,” in Metallography and Microstructures, vol. 9, 1985.
M. Geethaet, A. K. Singh, R. Asokamani, and A. K. Gogia, “Ti Based Biomaterials: The Ultimate Choice for Othopaedic Implants – a Review,” in Prog. In Mat. Sci, vol. 54, no. 3, pp. 397-425, 2009.
P. Tarínet, A. García Simón, N. M. Piris, J. M. Badía, and J. M. Antoranz, “Caracterización de las transformaciones de fase α a β de la aleación Ti6Al4V y de las características mecánicas y microestructurales obtenidas,” in Bol. de la Soc. Esp. de Cer. y Vid, vol. 43, no. 2, pp. 267-272, 2004.
K. Wang, “The use of titanium for medical applications in the USA,” in Mat. Sci. and Eng. A, vol. 213, no.1, pp. 134- 137, 1996.
M. Geetha, D. Durgalakshmi y R. Asokamani, “Biomedical implants: corrosion and its prevention - a review,” in Recent Patents on Corrosion Science, vol. 2, pp. 40-54, 2010.
American Society for Testing and Materials. ASTM-E 3, “Standard practice for microetching metals and alloys,” USA: ASTM International, 2007.
American Society for Testing and Materials, ASTM-E 407, “Standard guide for reparation of metallographic specimens,” USA: ASTM International, 2011.
Kristen A. Marino and E. A. Carter, “The effect of platinum on al diffusion kinetics in βNiAl: implications for thermal barrier coating lifetime”, in Acta Mat, vol. 58, no. 7, pp. 2726-2737, 2010.
Nó M.L. A. Ibarra, A. López-Echarri, E. H. Bocanegra, and J. San Juan, “Diffusion processes in Cu–Al–Ni shape memory alloys studied by mechanical spectros copy and in situ transmission electron microscopy at high temperatures,” in Mat. Sci. and Eng. A, vol. 442, no. 1, pp. 418–422, Dec. 2006.
Descargas
Publicado
Cómo citar
Número
Sección
Licencia
La revista ITECKNE se encuentra registrada bajo una licencia de Creative Commons Reconocimiento-NoComercial 4.0 Internacional Por lo tanto, esta obra se puede reproducir, distribuir y comunicar públicamente, siempre que se reconozca el nombre de los autores y a la Universidad Santo Tomás. Se permite citar, adaptar, transformar, autoarchivar, republicar y crear a partir del material, siempre que se reconozca adecuadamente la autoría, se proporcione un enlace a la obra original y se indique si se han realizado cambios.
La Revista ITECKNE no retiene los derechos sobre las obras publicadas y los contenidos son responsabilidad exclusiva de los autores, quienes conservan sus derechos morales, intelectuales, de privacidad y publicidad. Sin embargo esta facultada para editar, publicar, reproducir y distribuir tanto en medios impresos como digitales, además de incluir el artículo en índices internacionales y/o bases de datos, de igual manera, se faculta a la editorial para utilizar las imágenes, tablas y/o cualquier material gráfico presentado en el artículo para el diseño de carátulas o posters de la misma revista.